Discussion:
How to export netlist and sch from Eagle 3.55 for an Altium user
(too old to reply)
Aaron Archer
2012-04-02 17:30:02 UTC
Permalink
Hello, I am new here. I have been using Eagle 3.55 for about 12 years now, and I have been very happy with it. We have done many things with it, but one of my current designs is too much for it. I am sending the design over to a board house that uses Altium, and they have asked for the schematic and the netlist, as well as some other items I can provide. What I haven't found is a way to export the schematic ad netlist into an industry standard format that will allow the board house to finish this design without starting from scratch. Does anyone have any suggestions? I would imagine that someone has written a ULP by now.
Warren Brayshaw
2012-04-02 18:59:39 UTC
Permalink
Post by Aaron Archer
Hello, I am new here. I have been using Eagle 3.55 for about 12 years
now, and I have been very happy with it. We have done many things
with it, but one of my current designs is too much for it. I am
sending the design over to a board house that uses Altium, and they
have asked for the schematic and the netlist, as well as some other
items I can provide. What I haven't found is a way to export the
schematic ad netlist into an industry standard format that will allow
the board house to finish this design without starting from scratch.
Does anyone have any suggestions? I would imagine that someone has
written a ULP by now.
There is a ULP in the download section that may be of interest . Check it
out

ftp://ftp.cadsoft.de/eagle/userfiles/ulp/eagle2ad_sch.ulp

Warren
--
Viewed / responded via the newsgroup at
news.cadsoft.de
Aaron Archer
2012-04-02 19:23:00 UTC
Permalink
Unfortunately, that ULP will not run in 3.55. We are trying
netlist_protel.ulp right now to see if the output is usable for the
boardhouse.
--
Web access to CadSoft support forums at www.eaglecentral.ca. Where the CadSoft EAGLE community meets.
Warren Brayshaw
2012-04-03 07:30:59 UTC
Permalink
Post by Aaron Archer
Unfortunately, that ULP will not run in 3.55. We are trying
netlist_protel.ulp right now to see if the output is usable for the
boardhouse.
--
Web access to CadSoft support forums at www.eaglecentral.ca. Where
the CadSoft EAGLE community meets.
If you are still stuck yo could install a version 4 copy of Eagle
ftp://ftp.cadsoft.de/eagle/program/

I expect you design would load and then you could ty the ULP again

Warren
--
Viewed / responded via the newsgroup at
news.cadsoft.de
Loading...